P0151
129102 - P0151Information saved in
DME
Fault code
129102 - P0151
Fault text
Oxygen sensor before catalytic converter 2, signal lines:
Short to earth
Fault description
The diagnostic function monitors the messages of the
internal oxygen sensor chip.
Condition for fault identification
Test condition:
The fault is recognized by the self-diagnosis.
Potential problem source(s):
- Defect in wiring harness to pre-catalyst oxygen sensor 2
- Oxygen sensor 2 forward of catalytic converter defective
- Defective DME
Terminal condition: none
Voltage condition:
- None
Temperature condition:
- None
Time condition:
- 1 sec.
Other conditions:
- Engine on
- No additional diagnostic fault codes logged
Condition for fault memory entry
This fault is logged in the control module's fault memory if
it remains present for longer than 0.5 sec.
Action in service
- Defect in wiring harness to pre-catalyst oxygen sensor 2
- Replace pre-catalyst oxygen sensor 2
- Replace DME
Fault effect and breakdown warning
Breakdown notice:
- none
Possible apparent symptoms:
- none
Driver information
Warning light:
- ECE emissions warning lamp: on
- US emissions warning lamp: on
- ECE electronic engine power reduction: off
- US electronic engine power reduction: off
- CC message: none
Service instruction
- none