P110F
10B104 - P110FInformation saved in
DME
Fault code
10B104 - P110F
Fault text
Ambient-temperature sensor, electric: signal fault
Fault description
The diagnostic function monitors communications between
the instrument cluster and the DME related to ambient
temperature.
Condition for fault identification
Test condition:
The fault is recognized when the ambient temperature is not
transmitted.
Potential problem source(s):
- Wiring harness to outside temperature sensor defective
- Outside temperature sensor defective
Terminal condition: Terminal 15
Voltage condition:
- None
Temperature condition:
- None
Time condition:
- None
Other conditions:
- none
Condition for fault memory entry
This fault is logged in the control module's fault memory if
it remains present for longer than 22 sec.
Action in service
- Conduct fault diagnosis at the instrument cluster
Fault effect and breakdown warning
Breakdown notice:
- none
Possible apparent symptoms:
- Incorrect temperature display
Driver information
Warning light:
- ECE emissions warning lamp: off
- US emissions warning lamp: on
- ECE electronic engine power reduction: off
- US electronic engine power reduction: off
- CC message: none
Service instruction
- none