P151B
215208 - P151BInformation saved in
DME
Fault code
215208 - P151B
Fault text
Intelligent battery sensor, signal transfer: level, wake-up
line, implausible
Fault description
The diagnostic function monitors the wake-up wire.
Condition for fault identification
Test condition:
The fault is recognized when the signal level in the wake-up
wire is implausible.
Potential problem source(s):
- Wake-up line defective
- IBS defective
Terminal condition: none
Voltage condition:
- None
Temperature condition:
- None
Time condition:
- None
Other conditions:
- none
Condition for fault memory entry
This fault is logged in the control module's fault memory if
it remains present for longer than 20 sec.
Action in service
- Check wake-up wire for consistent and intermittent open
circuits
- IBS disconnected, Terminal 15 off, wake-up wire shorted
to positive: Check wake-up wire and other components
connected to the wake-up wire
- IBS disconnected, Terminal 15 off, wake-up wire shorted
to ground: Check wake-up wire
- IBS connected, Terminal 15 off, wake-up wire shorted to
positive: Replace IBS IBS connected, Terminal 15 on,
wake-up wire shorted to ground: Replace IBS
Fault effect and breakdown warning
Breakdown notice:
- none
Possible apparent symptoms:
- Anything from no symptoms to breakdown from
undercharged battery
Driver information
Warning light:
- ECE emissions warning lamp: off
- US emissions warning lamp: off
- ECE electronic engine power reduction: off
- US electronic engine power reduction: off
- CC message: none
Service instruction
- none