P15C5
215801 - P15C5Information saved in
DME
Fault code
215801 - P15C5
Fault text
Intelligent battery sensor (IBS): wake-up line, short circuit
to positive or ground
Fault description
The diagnostic function monitors the wake-up wire to the
junction box electronics.
Condition for fault identification
Test condition:
The fault is recognized when the wake-up wire has a short
circuit.
Potential problem source(s):
- Defect in wake-up wire from IBS to junction box
electronics
Terminal condition: none
Voltage condition:
- None
Temperature condition:
- None
Time condition:
- None
Other conditions:
- none
Condition for fault memory entry
This fault is logged in the control module's fault memory if
it remains present for longer than 20 sec.
Action in service
- Check wake-up wire between IBS and junction box
electronics
Fault effect and breakdown warning
Breakdown notice:
- none
Possible apparent symptoms:
- none
Driver information
Warning light:
- ECE emissions warning lamp: off
- US emissions warning lamp: off
- ECE electronic engine power reduction: off
- US electronic engine power reduction: off
- CC message: none
Service instruction
- none