P1625
1F3108 - P1625Information saved in
DME
Fault code
1F3108 - P1625
Fault text
Accelerator-pedal module, internal fault, channel 2: voltage
regulator
Fault description
The diagnostic function monitors the power-supply voltage
to sensor 2 on the accelerator pedal module.
Condition for fault identification
Test condition:
The fault is recognized when the power-supply voltage at
accelerator pedal module sensor 2 varies from 5V by more
than 0.21 V.
Potential problem source(s):
- Defect in power-supply voltage to sensor 2 at the
accelerator pedal module
- E7X: DME main relay displays lag when switching
- Defective DME
Terminal condition: Terminal 15
Voltage condition:
- None
Temperature condition:
- None
Time condition:
- None
Other conditions:
- none
Condition for fault memory entry
The diagnostic fault code is logged when the fault persists
for longer than 200 ms.
Action in service
Check power-supply voltage to pedal-travel sensor
- E7X: Determine whether a diagnostic fault code related to
the DME main relay has been logged
- Replace the DME
Fault effect and breakdown warning
Breakdown notice:
- The engine reverts to its limp-home program, continued
vehicle operation is possible but drivability is restricted,
because power is reduced the driver should refrain from
passing maneuvers.
Possible apparent symptoms:
- Power reduction
- Engine speed governed
Driver information
Warning light:
- ECE emissions warning lamp: off
- US emissions warning lamp: off
- ECE electronic engine power reduction: on
- US electronic engine power reduction: on
- CC message: on
Service instruction
- none