P165D
1B2202 - P165DInformation saved in
DME
Fault code
1B2202 - P165D
Fault text
DME, internal fault, EWS data: fault-activation-code storage
Fault description
The diagnostic function monitors whether the stored
information for the EWS contains errors.
Condition for fault identification
Test condition:
The fault is recognized when a fault is present in the enable
code memory.
Potential problem source(s):
- Enable code memory defective
Terminal condition: Terminal 15
Voltage condition:
- None
Temperature condition:
- None
Time condition:
- None
Other conditions:
- none
Condition for fault memory entry
This fault is logged in the control module's fault memory if
it remains present for longer than 1 sec.
Action in service
- Replace DME
Fault effect and breakdown warning
Breakdown notice:
- none
Possible apparent symptoms:
- None, because fault occurs only during EWS
synchronization, and this is possible only at the factory
Driver information
Warning light:
- ECE emissions warning lamp: off
- US emissions warning lamp: off
- ECE electronic engine power reduction: off
- US electronic engine power reduction: off
- CC message: none
Service instruction
- none