P16C2
200208 - P16C2Information saved in
DME
Fault code
200208 - P16C2
Fault text
DME, internal fault, monitoring engine-speed limitation:
malfunction
Fault description
The diagnostic function monitors internal operations within
the control module to ensure that they are executed
correctly.
(here relative to rpm limitation)
Condition for fault identification
Test condition:
The fault is recognized when an internal comparison detects
excessively high deviations.
Potential problem source(s):
- DME defective
Terminal condition: Terminal 15
Voltage condition:
- Electrical system voltage > 10 V
Temperature condition:
- None
Time condition:
- None
Other conditions:
- none
Condition for fault memory entry
This fault is logged in the control module's fault memory if
it remains present for longer than 0.5 sec.
Action in service
- If the diagnostic fault code has been entered with a
frequency > 3, then replace the DME
Fault effect and breakdown warning
Breakdown notice:
- Allow vehicle to enter sleep mode, then restart may resolve
the problem, although the remedy may only be temporary
Possible apparent symptoms:
- In extreme cases engine stalls and cannot be restarted
Driver information
Warning light:
- ECE emissions warning lamp: on
- US emissions warning lamp: on
- ECE electronic engine power reduction: on
- US electronic engine power reduction: on
- CC message: on
Service instruction
- none