Operation CHARM: Car repair manuals for everyone.

P16DC

CD8487 - P16DC

Information saved in
DME

Fault code
CD8487 - P16DC

Fault text
none

Fault description
The diagnosis monitors the FlexRay.

Condition for fault identification
Test condition:
The fault is recognized when the FlexRax fails to achieve
'Normal Active' status.
Potential problem source(s):
- FlexRay defect
Terminal condition: Terminal 15
Voltage condition:
- Electrical system voltage > 10 V
Temperature condition:
- None
Time condition:
- 750 sec.
Other conditions:
- none

Condition for fault memory entry
This fault is logged in the control module's fault memory if
it remains present for longer than 0.01 sec.

Action in service
- Check FlexRay

Fault effect and breakdown warning
Breakdown notice:
'- None
Possible apparent symptoms:
- DSC Failure
- Cruise control failure

Driver information
Warning light:
- ECE emissions warning lamp: off
- US emissions warning lamp: on
- ECE electronic engine power reduction: off
- US electronic engine power reduction: off
- CC message: none

Service instruction
- none