Operation CHARM: Car repair manuals for everyone.

P3250

119102 - P3250

Information saved in
DME

Fault code
119102 - P3250

Fault text
Rail-pressure sensor 2, electric: short circuit to ground

Fault description
The diagnostic function monitors rail-pressure sensor 2's
lower voltage limit.

Condition for fault identification
Test condition:
The fault is recognized when the voltage of the rail-pressure
sensor 2 is < 0.4 V.
Potential problem source(s):
- Defect in wiring harness
- Defective rail-pressure sensor
Terminal condition: Terminal 15
Voltage condition:
- None
Temperature condition:
- None
Time condition:
- None
Other conditions:
- none

Condition for fault memory entry
This fault is logged in the control module's fault memory if
it remains present for longer than 0.5 sec.

Action in service
- Check wiring harness
- Replace rail-pressure sensor 2

Fault effect and breakdown warning
Breakdown notice:
- none
Possible apparent symptoms:
- The engine runs roughly, can stall in extreme cases

Driver information
Warning light:
- ECE emissions warning lamp: on
- US emissions warning lamp: on
- ECE electronic engine power reduction: on
- US electronic engine power reduction: on
- CC message: none

Service instruction
- none