Surface Variation - Warpage
Important!
Reconditioning on cylinder head max. 0.3 mm
Checking Surface Variation - Warpage
Check evenness of cylinder head sealing faces with a standard straight-edge (1).
Note: Max. deviation from level (longitudinal) 0.10 mm
Check evenness of cylinder head sealing faces with a standard straight-edge (1).
Note: Max. deviation from level (transversal) 0.05 mm