67 62 020 Removing and Installing/Replacing Flat Motor For Rear Left or Right Power Window Regulator
67 62 020 Removing and installing/replacing flat motor for rear left or right power window regulator
Necessary preliminary tasks:
- Remove rear power window regulator
Release screws (1) and detach flat motor (2) from power window regulator.
Tightening torque 67 62 1AZ.
IMPORTANT: For installation of flat motor (3) without tension, fit pinion (2) in guide (1).
After installation:
An initialisation must be carried out in order to activate anti-trap mechanism.
Read and comply with notes on initialisation of power window regulator.