12 14 512 Replacing Pulse Generator on Left Exhaust Camshaft
12 14 512 Replacing Pulse Generator On Left Exhaust Camshaft (N74)
(cylinder bank 7 to 12)
Necessary preliminary tasks:
- Read out fault memory of DME control unit; if necessary, work through test schedules
- Turn off ignition
- Remove left intake silencer housing
- Remove left bulkhead sound insulation
- Remove left throttle body
Unlock plug (1) and remove.
Release screw (2).
Tightening torque 13 62 2AZ.
Remove pulse generator (3).
Installation:
Replace sealing ring and coat with antiseize agent.
NOTE:
Assemble engine.
Delete fault memory.