HVAC System - Manual
HVAC CONTROL MODULE REPLACEMENTREMOVAL PROCEDURE
1. Remove the I/P cluster trim plate bezel .
2. Remove the HVAC control module retaining screws.
3. Pull the HVAC control module straight out from the I/P.
4. Disconnect the HVAC control module electrical connector.
INSTALLATION PROCEDURE
IMPORTANT: The key should be in the off position when connecting the HVAC control module electrical connector to ensure proper calibration.
1. Connect the HVAC control module electrical connector.
2. Install the HVAC control module into the I/P opening.
NOTE: Refer to Fastener Notice in Service Precautions.
3. Install the HVAC control module retaining screws.
Tighten
Tighten the screws to 2.5 N.m (22 lb in).
4. Install the IP cluster trim plate bezel.
IMPORTANT: Do not adjust any controls on the HVAC control module while the HVAC control module is self-calibrating. If interrupted, improper HVAC performance will result. The engine must be running for proper calibration to occur.
5. Start and allow the engine to run for a least one minute.