Blower Motor Control Processor

BLOWER MOTOR CONTROL PROCESSOR REPLACEMENT

REMOVAL PROCEDURE
1. Remove the right side I/P insulator.




2. Disconnect the blower motor electrical connector.
3. Remove the blower motor mounting screws.
4. Remove the blower motor from the HVAC module assembly.




5. Disconnect the electrical connector from the blower motor control processor assembly.
6. Remove the forward blower control processor mounting screws.
7. Remove the rearward blower control processor mounting screw.




8. Remove the blower control processor assembly from the HVAC module assembly.

INSTALLATION PROCEDURE




1. Install the blower motor control processor assembly to the HVAC module assembly.

NOTE: Refer to Fastener Notice in Service Precautions.

2. Install the rearward mounting screw.

Tighten
Tighten the screw to 1.8 N.m (16 lb in).

3. Install the forward mounting screws.

Tighten
Tighten the screws to 1.8 N.m (16 lb in).




4. Connect the electrical connector to the blower control processor assembly.
5. Install the blower motor to the HVAC module assembly.
6. Install the blower motor mounting screws.

Tighten
Tighten the screws to 1.8 N.m (16 lb ft).




7. Connect the blower motor electrical connector.
8. Install the right side I/P insulator.