Operation CHARM: Car repair manuals for everyone.

A/C - Blower Motor Inoperative or Will Not Stop Running

90buick01

Bulletin 88-1-23A

Date Dec., '89

Ref. No. 89-139A-1

Corp. Ref. No. 831217R

SUBJECT: BLOWER MOTOR INOPERATIVE OR WILL NOT STOP RUNNING (NEW PARTS KIT)

MODELS AFFECTED: 1982-88 LESABRE AND ELECTRA ESTATE WAGON 1982-85 LESABRE 1982-84 ELECTRA AND PARK AVENUE 1982-87 REGALS 1982-85 RIVIERAS WITH C68 A/C

NOTICE: This bulletin has been revised to add the Regals and Rivieras and to correct the parts statement.


Some 1982-88 Buicks with C68 HVAC systems may exhibit the subject condition due to a shorted power transistor in the power module of the automatic HVAC system.

This condition may be addressed by the installation of a power module service kit, part number 10135631.

Parts are currently available from GMSPO.

Labor Operation Number: T1397

Labor Time: .5 Hours