A/C - Blower Motor Inoperative or Will Not Stop Running
90buick01Bulletin 88-1-23A
Date Dec., '89
Ref. No. 89-139A-1
Corp. Ref. No. 831217R
SUBJECT: BLOWER MOTOR INOPERATIVE OR WILL NOT STOP RUNNING (NEW PARTS KIT)
MODELS AFFECTED: 1982-88 LESABRE AND ELECTRA ESTATE WAGON 1982-85 LESABRE 1982-84 ELECTRA AND PARK AVENUE 1982-87 REGALS 1982-85 RIVIERAS WITH C68 A/C
NOTICE: This bulletin has been revised to add the Regals and Rivieras and to correct the parts statement.
Some 1982-88 Buicks with C68 HVAC systems may exhibit the subject condition due to a shorted power transistor in the power module of the automatic HVAC system.
This condition may be addressed by the installation of a power module service kit, part number 10135631.
Parts are currently available from GMSPO.
Labor Operation Number: T1397