Stop Solenoid, Replace
Fig. 50 MVS voltage chart:
Fig. 59 Exploded view of CAV pump:
1. Remove air cleaner and install cover J-26996-1
2. Clean dirt from area around solenoid.
3. Remove electrical lead.
4. Remove solenoid and O-ring, Fig. 59. Discard O-ring.
5. Reverse procedure to install. Torque solenoid to 130 inch lbs.