With Air Conditioning
1. Set FUNCTION SELECTOR in the A/C CONTROL HEAD to OFF, Blower Switch to LO, and Temperature Selector to COLD.^ Blower is off.
^ No air is flowing from any outlet.
2. Set Function Selector to MAX.
^ Engine idle increases and Compressor comes on.
^ Blower runs at low speed.
^ Air flows from Instrument Panel outlets.
^ Air from outlets gets colder.
3. Change Blower Switch from LO to M1, from M1 to M2, and from M2 to HI.
^ Air flow increases each time switch is moved to higher position.
^ Cold air flows only from Instrument Panel outlets.
4. Set Mode Selector to NORM.
^ Cold, high-speed air flows from instrument panel outlets.
^ Blower sound decreases as recirculating door opens to allow outside air to enter.
5. Put Mode Selector to BI-LEV.
^ High-speed air flows from instrument panel outlets and floor outlets.
6. Put Mode Selector to VENT.
^ Engine idle decreases and compressor goes off.
^ High-speed outside air flows from instrument panel outlets.
7. Put Mode Selector to HTR and Temperature Selector to HOT.
^ Warm, high-speed air flows from floor outlets.
^ No air flows from Instrument Panel outlets.
^ Small amount of air flows from windshield outlets.
8. Put Mode Selector to DEF.
^ Warm high-speed air flows from windshield outlets.
^ No air flows from Instrument Panel outlets.
^ Small amount of air flows from floor outlets.
9. Put Mode Selector to OFF.
^ Blower turns off.