Output
BCM OUTPUT DISPLAYS:When troubleshooting a malfunction, the BCM output cycling can be used to determine if the output tests can be actuated regardless of the inputs and normal program instructions. Once a test in outputs has been selected, the test will display "HI" and "LO" for three seconds in each state to indicate the command. Actual circuit operation will depend on circuit integrity. If the test selected is not allowed under the current conditions a " =- =- " display will result.
A brief summary of each output is provided below:
BO00 The "NO OUTPUTS" display will not display "HI" or "LO" as this is a resting spot where no outputs will be cycled.
BO01 The "CRUISE CONTROL VENT SOLENOID" display is "HI" when the vent solenoid is "ON" (energized). The cruise switch must be "ON" for this output to cycle.
BO02 The "CRUISE CONTROL VACUUM SOLENOID" display is "HI" when the cruise control vacuum solenoid is "ON" (energized). The cruise switch must be "ON" for this output to cycle.
BO03 The "RETAINED ACCESSORY POWER" (RAP) relay display is "LO" when the relays are "ON" (energized).
BO04 The "COURTESY RELAY" display is "LO" when the courtesy lamp relay is "ON" (energized).
BO06 The "HI/LO BEAM" relay display is "LO" when the relays is "ON" (energized), high beams are "ON."
BO10 The "CHIME 1" display is "LO" when the intermediate chime is "ON" (sounding).
BO11 The "CHIME 2" display is "LO" when the slow chime is "ON" (sounding).
BO12 The "FOGLAMP/DRL" display is "LO" when the relay is "ON." (Reatta only).
BO13 The "TWILIGHT" display is "LO" when the relay is "ON" (energized). (Riviera only).
The "PARKLAMPS" are "ON" when the relay is "LO." (Reatta only).
BO14 The "DRL" display is "LO" when the relays are "ON" (energized) lights "ON." (Riviera only).