Pump Motor Run Times
0-12,411 kPa (0-1800 psi) 10 to 30 seconds12,411-18,617 kPa (1800-2700 psi) 5 to 20 seconds
15,169-18,617 kPa (2200-2700 psi) 3 to 10 seconds
These numbers are dependent on battery voltage, accumulator precharge, and accumulator pressure switch contact points.
The total pump run time 0-18,617 kPa (0 to 2700 psi) should not exceed 40 seconds.