SIR Diagnostic System Check
The diagnostic procedures are designed to find and repair SIR malfunctions. To get the best results, it is important to use the diagnostic charts and follow the sequence listed below.
A. PERFORM THE "SIR DIAGNOSTIC SYSTEM CHECK."
The "SIR Diagnostic System Check" must be the starting point of any SIR diagnostics. The "SIR Diagnostic System Check" checks for proper "INFL REST" warning lamp operation, the ability of the DERM to communicate through the "Serial Data," and whether SIR diagnostic trouble codes exist.
B. REFER TO THE PROPER DIAGNOSTIC CHART AS DIRECTED BY THE "SIR DIAGNOSTIC SYSTEM CHECK."
The "SIR Diagnostic System Check" will lead you to the correct chart to diagnose any SIR malfunction. Bypassing these procedures may result in extended diagnostic time, incorrect diagnosis and incorrect parts replacement.
C. REPEAT THE "SIR DIAGNOSTIC SYSTEM CHECK" AFTER ANY REPAIR OR DIAGNOSTIC PROCEDURES HAVE BEEN PERFORMED.
Performing the "SIR Diagnostic System Check" after all repair or diagnostic procedures will ensure that the repair has been made correctly and that no other malfunction conditions exist.
CIRCUIT DESCRIPTION
When the ignition switch is first turned "ON" "Ignition 1" voltage is applied from Fuse 12 to the DERM at the "Ignition 1" input terminals "A3" and "B3" and from Fuse 17 to the DERM at the "SIR Indicator High" input. The DERM responds by flashing the "INFL REST" warning lamp 7 to 9 times while performing tests on the SIR system.
When the engine is being cranked, system voltage is applied from Fuse 20 to the DERM at the "Crank" input. The DERM responds by grounding the "SIR Indicator Low" output until system voltage is removed from the "Crank" input. This results in the "INFL REST" warning lamp being "ON" steady during cranking.
After cranking the DERM will again flash the "INFL REST" warning lamp 7 to 9 times and perform tests on the SIR system.
NOTES ON SYSTEM CHECK CHART
1. The "INFL REST" warning lamp should flash 7 to 9 times after ignition is first turned "ON."
2. The "INFL REST" warning lamp should remain "ON" steady during cranking.
3. After cranking, the "INFL REST" warning lamp should flash 7 to 9 times then go "OFF."
4. The "INFL REST" warning lamp has successfully completed the "Bulb Check."
5. This test checks for the proper operation of the "Serial Data" circuit. This test will also determine whether history diagnostic trouble codes are stored, if so, identify them.
6. Improper operation of the "INFL REST" warning lamp is indicated. This test differentiates a warning lamp stays "ON" condition from a warning lamp does not come "ON" condition.
7. This test differentiates a current diagnostic trouble codes exist condition from a "Flash Code" diagnostics enabled when not requested condition.
8. The "INFL REST" warning lamp has successfully completed "Bulb Check" and indicates current diagnostic trouble codes exist.
9. This test checks for proper operation of the "Serial Data" circuit. This test will also identify the stored diagnostic trouble codes and whether they are current or history.
DIAGNOSTIC AIDS
The order in which diagnostic trouble codes are diagnosed is very important. Failure to diagnose the diagnostic trouble codes in the order specified may result in extended diagnostic time, incorrect diagnosis, and incorrect parts replacement.