Operation CHARM: Car repair manuals for everyone.

Test G: False Alarm Test

^ If false alarm shuts OFF after 2 to 4 minutes, check for:
- Stuck or intermittent door latch or door lock assembly switch. Check for corrosion and loose connections.
- Stuck or intermittent tamper switch. Check for corrosion, loose connections, and properly installed retainer.
- Ground or intermittent ground in wiring associated with those switches.
^ If false alarm is continuous or intermittent for more than 2 to 4 minutes, check for:
- Ground or intermittent ground in wiring to Remote Accessory Control (RAC) module connector C3 (terminal H) if horns, or RAC module connector C3 (terminal G) if exterior lamps.
- Defective RAC module. If alarm stops when RAC Module is disconnected. replace RAC Module. Service and Repair