Troubleshooting Hints - Charging System
PERFORM BEFORE BEGINNING SYSTEM DIAGNOSIS1. Visually inspect the hydrometer (built into Battery).
^ Green dot - Battery is charged.
^ Dark dot - Charge and load test Battery. If Battery passes load test, refer to System Diagnosis.
^ Clear or light yellow dot-Battery electrolyte is low. Replace Battery.
2. Check U/Hood Fuse #8 and I/P Fuse #11. Check Maxifuse #11.
3. Check that the Generator Connector and Generator "BAT" terminal are both clean and tight.
4. Check that the Battery connections are clean and tight.
5. Check Generator belt.
^ Check for a broken (or partially broken) wire inside of the insulation which could cause system failure but prove "GOOD" in a continuity/voltage check (refer to General Troubleshooting Procedures). Diagnostic Aids
^ Check for proper installation of aftermarket electronic equipment which may affect the integrity of other systems (refer to General Troubleshooting Procedures). Diagnostic Aids
^ Refer to System Diagnosis.