Catalyst Monitor Diagnostic Operation

Three-Way Catalyst Oxygen Storage Capacity:









The OBD II catalyst monitor diagnostic measures oxygen storage capacity. In order to do this, the heated sensors are installed before and after the Three-Way Catalyst (TWC). Voltage variations between the sensors allow the control module to determine the catalyst emission performance. As a catalyst becomes less effective in promoting chemical reactions, the catalyst's capacity to store and release oxygen generally degrades. The OBD II catalyst monitor diagnostic is based on an correlation between conversion efficiency and oxygen storage capacity.

A good catalyst (e.g. 95 % hydrocarbon conversion efficiency) shows a relatively flat output voltage on the post-catalyst Heated Oxygen Sensor (HO2S). A degraded catalyst (65 % hydrocarbon conversion) shows a greatly increased activity in output voltage from the post catalyst HO2S.

The post-catalyst HO2S 2 is used to measure the oxygen storage and release capacity of the catalyst. A high oxygen storage capacity indicates a good catalyst; low oxygen storage capacity indicates a failing catalyst. The TWO, HO2S 2, and HO2S 3 must be at operating temperature in order to achieve correct oxygen sensor voltages like those shown in the Post-Catalyst HO2S 3 Outputs graphic.

The catalyst monitor diagnostic is sensitive to the following conditions:
^ Exhaust leaks
^ HO2S Contamination
^ Alternate fuels

Exhaust system leaks may cause the following results:
^ Prevent a degraded catalyst from failing the diagnostic
^ Cause a false failure for a normally functioning catalyst
^ Prevent the diagnostic from running

Some of the contaminants that may be encountered are phosphorus, lead, silica, and sulfur. The presence of these contaminants prevents the TWC diagnostic from functioning properly.

The control module must monitor the Three-Way catalyst system (TWC) for efficiency. In order to accomplish this, the control module monitors the pre-catalyst and post-catalyst oxygen sensors. When the TWO is operating properly, the post-catalyst (2) oxygen sensor will have significantly less activity than the pre-catalyst (1) oxygen sensor. The TWO stores oxygen as needed during its normal reduction and oxidation process. The TWO releases oxygen as needed during its normal reduction and oxidation process. The control module calculates the oxygen storage capacity using the difference between the pre-catalyst and post-catalyst oxygen sensor's voltage levels.

Whenever the voltage levels of the post-catalyst (2) oxygen sensor nears the voltage levels that of the pre-catalyst (1) oxygen sensor, the catalysts efficiency is degraded.

Stepped or staged testing levels allow the control module to statistically filter test information. This prevents falsely passing or falsely failing the oxygen storage capacity test. The calculations performed by the on-board diagnostic system are very complex For this reason, do not use post catalyst oxygen sensor activity in order to determine the oxygen storage capacity unless directed by the electronic service information

Three stages are used in order to monitor catalyst efficiency. Failure of the first stage indicates that the catalyst requires further testing in order to determine catalyst efficiency. Failure of the second stage indicates that the catalyst may be degraded. The third stage then looks at the inputs from the pre and post O2 sensors more closely before determining if the catalyst is indeed degraded. This further statistical processing is done to increase the accuracy of oxygen storage capacity type monitoring. Failing the first (stage 0) or second (stage 1) test Does Not indicate a failed Catalyst. The catalyst may be marginal or the fuel sulfur content could be very high.

Aftermarket HO2S characteristics may be different from the original equipment manufacturer sensor. This may lead to a false pass or a false fail of the catalyst monitor diagnostic. Similarly, if an Aftermarket catalyst does not contain the same amount of cerium as the original part, the correlation between oxygen storage and conversion efficiency may be altered enough to set a false DTC.