Operation CHARM: Car repair manuals for everyone.

Manifold Pressure/Vacuum Sensor: Service and Repair






REMOVE OR DISCONNECT
1. Remove the air cleaner outlet resonator.
2. Disconnect the MAP sensor electrical connector.
3. Remove the MAP sensor attaching screws (1).
4. Remove the MAP sensor vacuum hose (2).

INSTALL OR CONNECT
1. Connect the vacuum hose (2).
2. Install the MAP sensor attaching screw (1).
- Tighten the attaching screw to 4.5-7.5 Nm (4-6 lb. in.).
3. Connect the MAP sensor electrical connector.
4. Install the air cleaner outlet resonator.