Troubleshooting Hints - Heated Seats
1. Check HVAC Fuse. If open, repair circuit 41 for a short to ground.2. Check LH HEATED SEAT Fuse. If open, repair circuit 1440 for a short to ground.
3. Check RH HEATED SEAT Fuse. if equipped. If open, repair circuit 1940 fur a short to ground.
4. Check that G301 is clean and tight.
^ Check for a broken (or partially broken) wire inside of the insulation which could cause system malfunction but prove GOOD in a continuity/voltage check with a system disconnected. These circuits may be intermittent or resistive when loaded, and if possible, should be checked by monitoring for a voltage drop with the system operational (under load).
^ Check for proper installation of aftermarket electronic equipment which may affect the integrity of other systems. Refer to General Troubleshooting Procedures. Diagnostic Aids
^ Refer to System Diagnosis.