HVAC Programmer
HVAC Programmer Mounting Bracket:
HVAC Programmer:
Remove or Disconnect
1. Negative battery cable.
2. Right sound insulator.
3. I/P compartment.
4. Electrical connectors from programmer.
5. Retaining tabs from programmer.
6. Programmer.
Install or Connect
1. Programmer into retainer on bracket.
2. Electrical connectors to programmer.
3. I/P compartment.
4. Right sound insulator.
5. Negative battery cable.
Important
^ After the programmer has been replaced, the actuators need to be recalibrated for proper travel.
The ignition must be cycled ON for 3 minutes to allow the programmer and the actuators to recalibrate for proper travel.