Initial And Operational Setup
Complete Operational Setup:
Initial Setup
Refer to the manufacturer instructions for all initial setup procedures.
Operation Setup
Tool Required:
J 39500 Air Conditioning Refrigerant Recovery, Recycling and Recharging (ACR4) System
WARNING: Always wear goggles and gloves when doing work that involves opening the refrigeration system. If liquid refrigerant comes into contact with the skin or eyes, injury may result.
WARNING: Use only authorized 23 kg (50-pound) refillable refrigerant tanks (J 39500-50). Use of other tanks could cause personal injury and void the warranty.
NOTICE: Refrigerant-134a systems have special fittings (per SAE specifications) to avoid cross-contamination with Refrigerant-12 systems. Do not attempt to adapt this unit to Refrigerant-12 systems as severe system failure will result.
Connect high-side (red) and low-side (blue) hoses to the (ACR4) unit. Be sure to route hoses through hose reel bracket grommets.