Evaporator to Accumulator Line
Refrigerant Line Connection:
Refrigerant Lines And Routing:
Refrigerant Lines To Compressor:
Remove or Disconnect
1. Air cleaner and duct assembly.
2. Recover refrigerant. Refer to "Refrigerant Recovery and Recycling, Adding Oil, Evacuating and Recharging Procedures".
3. Liquid line/suction line bracket.
4. Suction line fitting at accumulator.
5. Suction line at block fitting bolt.
6. Suction line bracket at strut tower.
7. Suction line.
Important
^ Use care when removing tube.
8. O-rings.
Install or Connect
1. New O-ring seals coated with mineral base 525 viscosity refrigerant oil.
2. Suction line into place.
3. Suction line at block fitting bolt.
Tighten
^ Bolt to 16 N.m (12 lb. ft.).
4. Suction line fitting at accumulator.
Tighten
^ Fitting to 47 N.m (35 lb. ft.).
5. Suction line bracket at strut tower.
Tighten
^ Nut to 3.3 N.m (29 lb. in.).
6. Liquid line/suction line bracket.
7. Evacuate, recharge, and leak test system. Refer to Refrigerant Recovery and Recycling, Adding Oil, Evacuating and Recharging Procedures.
8. Air cleaner and duct assembly.