Vacuum System - Testing
IMPORTANT: To avoid misdiagnosis, complete Table #3, Air Flow from Outlets Is Incorrect, before beginning vacuum diagnosis. Table 3 Air Flow From Outlets Is Incorrect1. Check vacuum supply to vacuum/electric solenoid (purple and black vacuum hoses) while engine is running.
^ Vacuum should be approximately 60kPa (18psi) with engine running.
^ Vacuum should remain at approximately 60kPa (18 psi) when engine is turned off.
2. Test each vacuum actuator by disconnecting the vacuum hose and applying vacuum directly to the actuator. Repair or replace as necessary.
3. Reconnect all vacuum and electrical connections. Run engine and cycle through the operating modes of the heater-A/C control while observing the valve actuators.
Air Delivery Vacuum Distribution Table:
^ Check for vacuum to the mode valve actuators by noting mode valve actuator position. When vacuum is applied, the actuator will retract. Refer to Air Delivery Vacuum Distribution Table.
^ If a vacuum actuator retracts when it should not, replace the beater-A/C control.
^ If a vacuum actuator does not retract when it should, check for vacuum leaks, collapsed vacuum hoses or binding valves. If OK, replace the vacuum/electric solenoid.