Initial And Operational Setup
Operational Setup:
Tool Required:
J 39500 Air Conditioning Refrigerant Recovery, Recycling and Recharging (ACR4) System.
CAUTION: Always wear goggles and gloves when doing work that involves opening the refrigeration system. If liquid refrigerant comes Into contact with the skin or eyes, injury may result.
CAUTION: Use only authorized 23 kg 50-pound) refillable refrigerant tanks J 39500-50). Use of other tanks could cause personal Injury and void the warranty.
NOTICE: Refrigerant-134a systems have special fittings (per SAE specifications) to avoid cross-contamination with Refrigerant- 12 systems. Do not attempt to adapt this unit to Refrigerant-l2 systems as severe system failure will result.
Connect high-side (red) and low-side (blue) hoses to the (ACR4) unit. Be sure to route hoses through hose reel bracket grommets.