Transmitter Synchronization
The keyless entry transmitters may become out of synchronization with the remote function actuator (RFA) module under the following conditions:
^ When changing the transmitter battery.
^ Excessively pressing the transmitter buttons while out of the vehicles range.
When a transmitter becomes out of synchronization, only the panic feature will operate from the transmitter.
To resynchronize the transmitter, perform the following steps:
1. Hold the transmitter within the range of the vehicle.
2. Press and hold the transmitter LOCK (4) and UNLOCK (1) buttons simultaneously for 8 seconds.
When the transmitter is synchronized with the vehicle, the door locks will cycle. The horn will chirp and the exterior lights will flash if programed to do these functions.