Troubleshooting Hints
PERFORM BEFORE BEGINNING SYSTEM DIAGNOSIS1. Check the IP fuse block PARK LPS/INT LPS Fuse 6C by visual inspection. If open, check for a short to ground in CKT 240 (ORN).
2. Check the IP fuse block FOG LPS Fuse 6D by visual inspection. If open, check for a short to ground in CKT 1440 (ORN).
3. If the park lights do not operate properly, refer to Exterior Lights. Testing and Inspection
4. If one fog light does not operate, check bulb, socket and related wiring.
5. Check that grounds G201 and G202 are clean and tight.
6. Before component replacement, check for poor connections at related component and in-line harness connector terminal connections.
7. Check for broken (or partially broken) wire inside of the insulation which could cause a system malfunction but prove good in a continuity/voltage check with a system disconnected. These circuits may be intermittent or resistive when loaded, and if possible, should be checked by monitoring for a voltage drop with the system operational (under load).
8. Check for proper installation of aftermarket electronic equipment which may affect the integrity of other systems.