Operation CHARM: Car repair manuals for everyone.

3 Way Catalytic Converter

REMOVAL PROCEDURE

Tools Required

J 29800 Cut-Off Tool

1. Service the front pipe and the catalytic converter as a single unit.

2. Remove the oxygen sensor. Refer to Oxygen Sensor Replacement in Engine Controls.

3. Support the converter.

Description:





4. Cut the intermediate exhaust pipes (1) at the converter with a J 29800 or equivalent. Cut the pipe as close to the weld as possible.

Description:





5. Remove the front pipe bolts at the exhaust manifold.

6. Remove the converter.

7. Remove the inlet/outlet portions that remain from the intermediate pipe/resonator.



INSTALLATION PROCEDURE

1. Install the converter.

2. Position the intermediate pipe/resonator for proper clearance to the underbody.

NOTICE: Refer to Service Precautions / Fasteners.

Description:





3. Install the U bolt type clamps.
^ Tighten the nut to 40 Nm (30 ft. lbs.).

4. Install the front pipe attaching bolts.
^ Tighten the bolts to 25 Nm (18 ft. lbs.).

5. Install the oxygen sensor. Refer to Oxygen Sensor Replacement in Engine Controls.
^ Tighten the to 41 Nm (30 ft. lbs.).