Auxiliary Lighting Package
The Body Control Module (SBM) allows the Remote Function Actuator (RFA) module to control the interior lighting through CKT 1393 (DK BLU). When the keyless entry transmitter is used for a remote lock or unlock function, the RFA will activate the auxiliary lighting input on the SBM. The SBM will then activate the theatre dim-1 and theatre dim-2 outputs for up to 15 seconds. After the 15 seconds, the SBM will enter the delayed illumination mode for another 25 second period. A door open input will end the auxiliary lighting mode and the SBM will begin the delayed illumination mode. If the ignition switch is turned to RUN, the theatre dim-1 and theatre dim-2 outputs will be deactivated. The outputs will also be deactivated if the lock all doors switch is activated. The SBM will not perform another auxiliary lighting function until the input transitions from inactive to active.