Operation CHARM: Car repair manuals for everyone.

Suction Line (Evaporator to Accumulator)

Refrigerant Line Connection To Cowl:




Refrigerant Lines And Routing:




Refrigerant Lines To Compressor:






Remove or Disconnect

1. Air cleaner and duct assembly.
2. Recover refrigerant.
3. Brake pressure modulator bracket.
4. Liquid line/suction line bracket.
5. Suction line fitting at accumulator.
6. Suction line at block fitting bolt.
7. Suction line bracket at strut tower.
8. Suction line.

Important
^ Use care when removing tube.

9. O-rings.

Install or Connect

1. New O-ring seals coated with mineral base 525 viscosity refrigerant oil.
2. Suction line into place.
3. Suction line at block fitting bolt.

Tighten
^ Bolt to 16 N.m (12 lb. ft.).

4. Suction line fitting at accumulator.

Tighten
^ Fitting to 47 N.m (35 lb. ft.).

5. Liquid line/suction line bracket.
6. Brake pressure modulator bracket.
7. Evacuate, recharge, and leak test system
8. Air cleaner and duct assembly.