Ignition & Key Alarm Switch
Tilt Steering Column - Part 1 Of 2:
Tilt Steering Column - Legend - Part 2 Of 2:
^ Tools Required:
- J 41352 Modular Column Holding Fixture
REMOVE OR DISCONNECT
1. Do steps 1 through 9 under REMOVE OR DISCONNECT, in LOWER SHROUD, UPPER SHROUD.
2. Do steps 2 through 5 under REMOVE OR DISCONNECT, in T/S & MULTIFUNCTION SWITCH ASM.
Removing Alarm Switch:
3. Key alarm switch from lock module assembly (15).
^ Gently pry retaining clip on alarm switch with small blade screwdriver.
^ Rotate alarm switch 1/4 turn and remove.
Remove Ignition And Key Alarm Switch:
4. Two tapping screws (18).
5. Ignition & key alarm switch assembly (19).
^ Wire harness from slot in steering column tilt head assembly (26).
INSTALL OR CONNECT
NOTICE: Always use the correct fastener in the proper location. When you replace a fastener, use ONLY the exact part number for that application. The manufacturer will call out those fasteners that require a replacement after removal. The manufacturer will also call out the fasteners that require thread lockers or thread sealant. UNLESS OTHERWISE SPECIFIED, do not use supplemental coatings (paints, greases, or other corrosion inhibitors) on threaded fasteners or fastener joint interfaces. Generally, such coatings adversely affect the fastener torque and joint clamping force, and may damage the fastener. When you install fasteners, use the correct tightening sequence and specifications. Following these instructions can help you avoid damage to parts and systems. Failure to do so may result in component damage or malfunction of steering column.
1. Ignition & key alarm switch assembly (19).
^ Route wire harness through slot in steering column tilt head assembly (26). Secure wire harness with a wire harness strap (22) through hole located in the bottom of housing assembly (26).
2. Two tapping screws (18).
Tighten
Tighten screws (18) to 1.5 Nm (13 inch lbs).
3. Key alarm switch to lock module assembly (15).
A. Switch with retaining clip parallel to lock cylinder (17).
B. Rotate switch 1/4 turn until locked into place.
4. Do steps 3 through 6 under INSTALL OR CONNECT, in T/S & MULTIFUNCTION SWITCH ASM.
5. Do steps 4 through 15 under INSTALL OR CONNECT, in LOWER SHROUD, UPPER SHROUD.