Generator Brace Replacement
REMOVAL PROCEDURE
1. Loosen the generator pivot bolt (1).
2. Remove the generator rear brace nut (4).
3. Remove the generator rear brace.
INSTALLATION PROCEDURE
1. Install the generator rear brace.
2. Finger start the generator pivot bolt (1).
3. Finger start the generator rear brace nut (4).
NOTE: Refer to Fastener Notice in Cautions and Notices.
4. Tighten the generator bolt and nut as described:
Tighten
4.1. Tighten the generator pivot bolt (1) to 50 N.m (37 lb ft).
4.2. Tighten the generator rear brace nut (4) to 25 N.m (18 lb ft).