Instrument Panel (IP) - Trim Panel Replacement - Right
REMOVAL PROCEDURE
1. Remove the right IP end cap.
2. Remove the right IP accessory trim plate.
3. Remove the right IP trim plate fastener (2) from the right IP end cap area.
4. Gently pry the right IP trim plate (1) rearward in order to disengage the retainers.
The retainers are located on the center most edge of the right trim plate.
INSTALLATION PROCEDURE
1. Snap the right IP trim plate (1) into the IP.
NOTE: Refer to Fastener Notice in Cautions and Notices.
2. Install the fasteners (2) to the IP.
Tighten
Tighten the fastener to 2 N.m (18 lb in).
3. Install the right IP accessory trim plate.
4. Install the right IP end cap.