Operation CHARM: Car repair manuals for everyone.

Generator Brace Replacement




REMOVAL PROCEDURE
1. Remove the fuel injector sight shield.
2. Remove the EVAP canister purge valve.
3. Remove the generator rear brace nut (2).
4. Remove the generator rear brace bolt (1).
5. Remove the generator rear brace.

INSTALLATION PROCEDURE
1. Install the generator rear brace.
2. Finger start the generator rear brace bolt (1).
3. Finger start the generator rear brace nut (2).

NOTE: Refer to Fastener Notice in Cautions and Notices.

4. Tighten the generator bolts in the order described. The following is a mandatory torque sequence:
4.1. Tighten
Tighten the generator rear brace bolt (1) to 50 N.m (37 lb ft).
4.2. Tighten
Tighten the generator rear brace nut (2) to 50 N.m (37 lb ft).
5. Install the EVAP canister purge valve.
6. Install the fuel injector sight shield.