EGR Closed Val. Pintle Position
Scan Tool Range
0.0 to
5.0 Volts. Represents the learned voltage that the
PCM uses to determine whether or not the
EGR valve is fully closed (
0 percent pintle position). If the Desired
EGR Position is
0% and a difference of more than
0.4 volt between EGR Feedback and EGR Closed Valve Pintle Position is detected, DTC P1404 will set.