IP Outlet Valve Replacement
REMOVAL PROCEDURE1. Remove the LH and RH insulators.
2. Remove the knee bolster.
3. Remove the floor console, if equipped.
4. Disconnect the defroster/vent valve link at the vent valve on the LH side of the HVAC module.
5. Remove the heater outlet cover retaining screws.
IMPORTANT: Position the heater outlet cover downward and rearward in order to disconnect the cover from the rear floor area duct assembly.
6. Remove the heater outlet cover.
7. Remove the vent valve (1) from the HVAC module.
INSTALLATION PROCEDURE
IMPORTANT: Align the vent valve into the HVAC module case.
1. Install the vent valve (1) into the HVAC module.
2. Install the heater outlet cover.
NOTE: Refer to Fastener Notice in Service Precautions.
3. Install the heater outlet cover retaining screws.
Tighten
Tighten the heater outlet cover screws to 1.5 N.m (13 lb in).
4. Connect the defroster/vent valve link to the vent valve on the LH side of the HVAC module.
5. Install the floor console, if equipped.
6. Install the knee bolster.
7. Install the LH and RH insulators.