HO2S 1
TOOLS REQUIRED
J 39194-B Heated Oxygen Sensor Socket
REMOVAL PROCEDURE (HO2S1)
The heated oxygen sensor may be difficult to remove when engine temperature is below 48°C (120°F). Excessive force may damage threads in exhaust manifold or exhaust pipe.
1. Disconnect the electrical connector.
2. Using J 39194-B Heated Oxygen Sensor Socket carefully back out the heated oxygen sensor.
INSTALLATION PROCEDURE (HO2S1)
1. Turn OFF the ignition.
2. Disconnect the electrical connector.
IMPORTANT: A special anti seize compound is used on the heated oxygen sensor threads. The compound consists of graphite suspended in fluid and glass beads. The graphite will hum away, but the glass beads will remain, making the sensor easier to remove. New or service sensors will already have the compound applied to the threads. If a sensor is removed from an engine and if for any reason is to be reinstalled, the threads must have anti seize compound applied before reinstallation.
3. Coat the threads of heated oxygen sensor/catalyst monitor with anti seize compound P/N 5613695, or equivalent if necessary.
NOTE: Refer to Fastener Notice in Service Precautions.
4. Install the Heated Oxygen Sensor.
Tighten
Tighten the HO2S 1 (Pre-catalytic converter) to 42 ± N.m (31 lb ft).
5. Connect the electrical connector.