Generator PWM
Scan Tool Range
0 percent to
100 percent. This represents the field terminal input from the generator. The field PWM duty cycle indicates generator output level. A higher duty cycle indicates a higher generator output. The
PCM uses the generator F terminal signal to adjust the spark and the
IAC in order to compensate for variances in engine load caused by the generator.