IAT Sensor
Scan Tool Range
-40°C to
151°C (
-40°F to
304°F). The
PCM converts the resistance of the
intake air temperature sensor to degrees. The PCM uses intake air temperature (
IAT) to adjust the fuel delivery and the spark timing according to incoming air density. The IAT is also compared to The ECT at start-up in order to identify cold starts for the
HO2S heater and the
[1][2]EVAP diagnostics.