Loop Status
Scan Tool Displays OPEN or CLOSED. Closed Loop indicates that the
PCM is controlling fuel delivery according to the
oxygen sensor voltage. In Open Loop, the PCM ignores the oxygen sensor voltage and bases the amount of fuel to be delivered on
throttle position (TP) sensor, engine coolant, and MAF sensor inputs only.