Exhaust Gas Recirculation: Service and Repair
REMOVAL PROCEDURE
1. Turn OFF the ignition switch.
2. Disconnect the electrical connector (5) from the EGR valve (1).
3. Remove the 2 EGR valve retaining nuts (4).
4. Remove the EGR valve from the EGR valve adapter (3).
5. Remove the gasket (2) from the EGR valve adapter.
INSTALLATION PROCEDURE
1. Install a new gasket (2) on the EGR adapter (3).
2. Position the EGR valve (1) to the EGR valve adapter.
NOTE: Refer to Fastener Notice in Service Precautions.
3. Install the 2 nuts (4) to the EGR valve (1).
Tighten
Tighten the nuts to 25 Nm (18 lb ft).
4. Connect the electrical connector (5) to the EGR valve (1).