Scan Tool Data Definitions - Remote Function Actuator (RFA)
8 Digit GM Part Number: Scan tool displays: part number - Display indicates the part number of the RFA.Battery Voltage: Scan tool displays: volts - Display indicates the battery voltage input, 0 - 30 volts is the operating range.
Courtesy Lamp Output: Scan tool displays: On/Off - Display indicates the commanded state of the courtesy lamps.
Exterior Lamp Output: Scan tool displays: On/Off - Display indicates the commanded state of the exterior lights.
Park Lamp input: Scan tool displays: On/Off - Display indicates the state of the park lamp switch.
Perimeter Lamp Output: Scan tool displays: On/Off - Display indicates the commanded state of the perimeter lights.
Calibration ID: Scan tool displays: number - Display indicates the 4 digit calibration ID of the RFA.
PROM ID: Scan tool displays: number - Display indicates the 4 digit PROM ID of the RFA.