B0602
CIRCUIT DESCRIPTIONDTC B0602 indicates that the instrument cluster detects a Phase Lock Loop (PLL) oscillator synchronization error.
CONDITIONS FOR SETTING THE DTC
The DTC B0602 sets when the instrument cluster detects a Phase Lock Loop (PLL) oscillator synchronization error during a diagnostic system self-test.
ACTION TAKEN WHEN THE DTC SETS
When the DTC B0602 sets, the instrument cluster illuminates the SERVICE VEHICLE SOON indicator.
DIAGNOSTIC AIDS
DTC B0602 is an unrecoverable error. The PLL oscillator is not serviceable. Replace the instrument cluster. Refer to IP Cluster Replacement