Fuel Tank Pressure Sensor: Service and Repair
REMOVAL PROCEDURE1. Turn OFF the ignition.
2. Remove the trunk liner.
3. Remove the nuts retaining the fuel sender access panel.
4. Remove the fuel sender access panel.
5. Disconnect the electrical connector from the fuel tank vapor pressure sensor.
6. Remove the fuel tank vapor pressure sensor (7) from the modular fuel sender assembly.
INSTALLATION PROCEDURE
1. Install the new fuel tank vapor pressure sensor (7) to modular fuel sender.
2. Connect the electrical connector to the fuel tank vapor pressure sensor.
3. Install the fuel sender access panel.
NOTE: Refer to Fastener Notice in Service Precautions.
4. Install the nuts retaining the fuel sender access panel.
Tighten
Tighten the fuel sender access panel nuts to 10 N.m (8 lb ft).
5. Install the trunk liner.