A/C Refrigerant Pressure Sensor Replacement
A/C REFRIGERANT PRESSURE SENSOR REPLACEMENTTOOLS REQUIRED
J 39400-A Halogen Leak Detector
REMOVAL PROCEDURE
1. Remove the air cleaner assembly.
2. Disconnect the A/C refrigerant pressure sensor from the electrical connector.
3. Remove the A/C refrigerant pressure sensor from the condenser tube.
INSTALLATION PROCEDURE
IMPORTANT: Lubricate a new O-ring seal with mineral base 525 viscosity refrigerant oil.
1. Install the new O-ring seal. Refer to O-ring Replacement.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the A/C refrigerant pressure sensor to the condenser tube.
Tighten
Tighten the A/C refrigerant pressure sensor to 4.7 N.m (41 lb in).
3. Connect the A/C refrigerant pressure sensor to the electrical connector.
4. Install the air cleaner assembly.
5. Leak test the fittings of the component using J 39400-A.